Commercial Fire Alarm
A commercial fire alarm permit is required for the following work on a commercial building or structure.
- Renovate and repair existing fire alarm systems, including suppression system supervisory and alarm systems.
- Extend or modify an existing fire alarm system, including suppression system supervisory and alarm systems.
- Installation of a new fire alarm system, including suppression system supervisory and alarm systems.
Please see Permit Home for the definition of commercial structures and work types. Please see work not requiring a permit for work that can be performed without a PLI permit. Please visit our Contacts page for the Construction Inspector's contact information.
New System Work Scopes:
The new system work type applies to the installation of new systems. The applicant shall identify one or more of the following work scopes:
- Automatic Smoke Detection System: installation of a fire alarm system for which automatic detectors serve as system initiating devices.
- Emergency Voice/Alarm Communication System: installation of an emergency voice/alarm communication system.
- Manual Fire Alarm System: installation of a fire alarm system that includes manual initiating devices.
- Manual Fire Alarm System with occupant notification only: installation of a fire alarm system for which activation of a suppression system initiates the system.
- Suppression System Monitoring System: installation of a fire alarm system that is limited to monitoring of a suppression system.
- Phased Work – Core & Shell: installation of systems associated with a phased building permit with a core and shell work scope. Work associated with the fit-out is not permitted. Selected in addition to one or more other work scopes.
- Phased Work – Fit-out: installation of systems associated with a phased building permit with fit-out work scope. Work associated with the core and shell is not permitted. Selected in addition to one or more other work scopes.
Addition / Alteration Work Scopes:
The addition/alteration work type applies to the alteration of an existing system. The applicant shall identify one or more of the following work scopes:
- Automatic Smoke Detection System: alteration of a fire alarm system for which automatic detectors serve as system initiating devices.
- Emergency Voice/Alarm Communication System: alteration of an emergency voice/alarm communication system.
- Manual Fire Alarm System: alteration of a fire alarm system that includes manual initiating devices.
- Manual Fire Alarm System with occupant notification only: alteration of a fire alarm system for which activation of a suppression system initiates the system.
- Suppression System Monitoring System: alteration of a fire alarm system that is limited to monitoring of a suppression system.
- Circuit Wiring: alteration of fire alarm circuit wiring.
- Fire Alarm Control and/or Annunciator Panel: installation of new or replacement fire alarm control and/or annunciator panels.
- Initiating Devices: installation or modification of initiating devices.
- Occupant Notification Devices: installation or modification of occupant notification devices.
- Emergency Replacement of device/equipment: repair and/or replacement of elements condemned by PLI and/or damaged elements required to maintain safe occupancy of an occupied building. Replacement of a fire alarm control panel is permitted under this work scope.
- Removal of System: removal of a system that is not replaced.
Minor Alteration Work Types:
The minor alteration work type applies to the modification of an existing system in an existing building with a valid certificate of occupancy. The applicant shall identify one or more of the following work scopes:
- Relay for Hood Suppression System: installation or modification of a relay for a hood suppression system.
- Relocation / Replacement of Devices In-Kind only: applies to the relocation or replacement in kind (same type and number) of devices (notification and/or initiating). Replacement and/or relocation of a fire alarm control panel is NOT permitted under this work scope.
- Emergency Repairs: repairs to equipment condemned by PLI and/or damaged equipment. Replacement of a fire alarm control panel is NOT permitted under this work scope.
Permit Process:
See these web pages for additional information regarding the permitting process:
- Permit Process
- Application Submission
- All other work types other than Minor Alterations require submission of construction drawings to OneStopPGH.
- Drawings shall be one of the following:
- Prepared and sealed by a PA-licensed architect or engineer.
- Prepared and sealed by a PA-licensed architect or engineer supplemented by shop drawings if accompanied by a statement from the architect or engineer that they have accepted the shop drawings as part of the construction drawings.
- Prepared and signed by an individual with a Level III Nicet certification for fire alarm systems.
- Application Review
- Permit Issuance
- Permit Inspections
- Statement of Compliance - required to be submitted for a final inspection.
- Record of Completion – required to be submitted for a final inspection.
- Permit Completion
Please see Other Agency Coordination for processes related to other agencies that may relate to your permit scope. For commercial fire alarm permits:
- Zoning Code Regulations: :
- Development of a property in a regulated floodplain requires a PLI Floodplain permit.
- PA Department of Health (DOH)
- Required for a structure regulated by the PA Health Care Facilities Act.